Finned Tube Heat Exchanger Demonstrational Equipment Vocational Education Equipment Thermal Lab Equipment

Item No.: WL 110.05
Finned Tube Heat Exchanger Demonstrational Equipment Vocational Education Equipment Thermal Lab Equipment
Description
WL 110.05 Finned Tube Heat Exchanger Demonstrational Equipment Vocational Education Equipment Thermal Lab Equipment

Heat transfer between water and air; cross-flow operation
Features
- heat transfer between water and air in cross-flow
- intuitive experiment execution via
touch screen
- integrated router for operation and control via an end device and for screen mirroring on up to 10 end devices: PC, tablet, smartphone
- automatic identification of accessories via RFID technology
Learning objectives/experiments
- in conjunction with WL 110 supply unit
-- function and behaviour of a finned tube heat exchanger
-- determine the mean heat transfer coefficient
-- influence of heat capacity
-- compare with other heat exchanger types
- PLC software specifically adapted to the accessories used
-- learning module with theoretical fundamentals
-- device description
-- guided experiment preparation
-- execution of the experiment
-- graphical representation of: experimental section with measured values for temperature, heat fluxes on both sides of the heat exchanger
-- data transfer via WLAN/LAN for versatile external use of the measured values and screenshots, e.g. evaluation in Excel


Specification
[1] finned tube heat exchanger for connection to WL 110
[2] heat transfer between water and air in cross-flow
[3] supply and exhaust air duct with transparent front wall for a clear view of the heat exchanger
[4] air flow generated by axial fan
[5] water temperature recorded via WL 110 and additionally 2 temperature sensors for recording the air temperature and 1 sensor for recording the flow velocity
[6] automatic identification of accessories via RFID technology and provision of the appropriate PLC software
[7] experiments execution and display of the measured values via touch screen (HMI)
[8] screen mirroring: access to ongoing experiments and experimental results from up to 10 terminals simultaneously via the local network
[9] hot water supplied via WL 110
Technical data
Finned tube heat exchanger
- pipe section
-- Ø inner: 12mm
-- material: copper
- fins
-- number: 33
Axial fan
- max. volumetric flow rate:: 170m3/h
- power consumption: 6,5W
Measuring ranges
- temperature: 2x 0...100°C
- flow velocity: 0...2,5m/s
LxWxH: 617x243x307mm