whatsapp: 0086-18615575385
whatsapp: 0086-13668821631

Electrical Testing In A Building Vocational Training Equipment Electrical Engineering Training Equipment

Item No.: PDG-1
PDG-1 Electrical Testing In A Building Vocational Training Equipment Electrical Engineering Training Equipment
Description
PDG-1 Electrical Testing In A Building Vocational Training Equipment Electrical Engineering Training Equipment

This panel can be used by teachers for their lessons and by students for an easy learning and testing on electrical prevention systems supplying them with the means for verifying the rule of art and the relevant technical standards.
TRAINING PROGRAM:
This panel can be used to define the electrical installations of a building (power distribution via TT system) with reference to the following topics:
• Design documents complying with CEI standard 0-2; predesign, definite project
• Electrical installation of the building complying with CEI guide 64-50 2nd edition
• Graphic symbols for installation plans
• Branch exchange for a flat
• Meter room and riser
• Earthing system for the block of flats
Furthermore, this panel is designed to deal with topics, visual checks, tests concerning:
• Protection systems against direct and indirect contacts
• Choice of conductors, current-carrying capacity and voltage drop
• Testing the paths of conductors and their suitability and duct diameter and removableness of conductors
• Suitability of materials and of equipment
• Protection and breaking devices
• Identification of neutral and earth conductors
• Suitability of the connections of conductors
• Continuity of protection and equipotential conductors
• Isolation resistance

TECHNICAL SPECIFICATIONS:
Framework is made of sheet steel chemically treated and painted with several coats of epoxy varnish; its base is provided with rubber feet and it can be positioned on a working top.
All the necessary electric components for the correct power supply of circuits are included in the panel.
Main components installed:
• 1 single-phase isolation transformer 230 V / 230 V 230 VA
• 2 simulators of earth plate with resistors of 2 Ω, 20Ω, 200 Ω, 2 kΩ
• 1 simulators of resistance of protection conductor with resistors of 0.1 Ω, 1 Ω
• 1 simulator of extraneous conducting part with resistances of 200 Ω, 1000 Ω, 5000 Ω
• 1 magnetothermal circuit breaker 2 x 2 A “C”
• 1 magnetothermal circuit breaker 2 x 1 A “C”
• 1 differential circuit breaker 2 x 1.6 A “C” / 30 mA “AC”
• 1 magnetothermal and differential circuit breaker 2x25 A/30 mA “A”
• 1 protection and control switch – 2P +Earth
• Two 2-pin sockets – 10/16 A, 2P + Earth
• 2 simulators of isolation earth fault in power consuming
• Device with resistors of 50 kΩ, 15 kΩ, 5 kΩ, 1500 Ω, 500 Ω, and bolted fault
Dimensions of demonstration panel: 800 x 600 mm
Dimensions of framework: 840 x 450 x 680 mm
Net weight: 33 kg
Supply with 
THEORETICAL – EXPERIMENTAL HANDBOOK