whatsapp: 0086-18615575385
whatsapp: 0086-13668821631

Set Of Protection Relays For High-Voltage And Low-Voltage Networks Educational Equipment Electrical Training Panel

Item No.: SRT-1
SRT-1 Set Of Protection Relays For High-Voltage And Low-Voltage Networks Educational Equipment Electrical Training Panel
Description
SRT-1 Set Of Protection Relays For High-Voltage And Low-Voltage Networks Educational Equipment Electrical Training Panel

This system has been designed to enable students to connect and apply a wide range of electric, electronic protection relays with circuits of increasing complexity, besides verifying their characteristics.
TECHNICAL CHARACTERISTICS:
Set of modules for studying static protection relays and measuring transformers:
1 Module SR-1
1 three-phase maximum-current and short-circuit relay, adjustment range 0,5-2A/1-16 A ac, auxiliary power supply of 230 V 50-60 Hz.
1 Module SR-2
1 single-phase maximum or minimum current relay, adjustment range 0.1-5A/ 5-25 A ac/dc, auxiliary power supply of 230 V 50- 60 Hz.
1 Module SR-3
1 three-phase maximum and minimum voltage relay /N, adjustment range +10% / -15%, Ue 380-400 Vac, self-powered.
1 Module SR-4
1 single-phase maximum or minimum voltage relay, adjustment range 2-500 Vac/dc, auxiliary power supply of 230 V 50-60 Hz.
1 Module SR-5
1 maximum and minimum frequency relay, 50-60 Hz, adjustment range + 10%, self-powered at 230 Vac.
1 Module SR-6
1 phase sequence and voltage asymmetry relay for networks of 400 V, asymmetry adjustment range: 5 -15%, self-powered at 400 Vac.
1 Modulo SR-7
1 auxiliary relay with two exchange contacts, driven by TTL/PLC signals / buttons of 24 Vdc for excitation, stop, start.
1 Module SR-8
1 auxiliary relay with two exchange contacts, excitation 24 Vdc, 1 optical acoustic indicator of 24 Vac/dc.
1 Module SR-9
1 timer relay with one exchange contact, multi-function, multirange, multi-voltage, 24 Vac/dc
1 Module SR-10
directional overcurrent relay, 5 A - 400 V, auxiliary power supply of 230 Vac.
1 Module SR-11
3 wound-primary current transformers 10/5 A, performance 3 VA in cl. 0.5.
1 Module SR-12
voltage transformers 500/100 V, performance 10 VA in cl. 0.5.
1 Module SR-13
1 current step-up transformer 5 + 5 + 5/5 A, performance 8 VA in cl. 0.5

TRAINING PROGRAM:
• Connections and study of the behaviour of a maximumcurrent relay in a three-phase network with different current values, verifi cation of trip time.
• Connections and study of the behaviour of a short-circuit current relay in a three-phase network with different current values, verifi cation of trip time.
• Connections and study of the behaviour of a single-phase maximum or minimum current relay, verifi cation of trip time for maximum and minimum current.
• Connections and study of the behaviour of a maximum or minimum DC relay, verifi cation of trip time for maximum and minimum current.
• Connections and study of the behaviour of a maximum and minimum voltage relay in a three-phase network with neutral, verifi cation of trip time for maximum and minimum voltage.
• Connections and study of the behaviour of a single-phase maximum or minimum voltage relay, verifi cation of trip time for maximum and minimum voltage.
• Connections and study of the behaviour of a maximum and minimum DC voltage relay, verifi cation of trip time for maximum and minimum voltage.
• Connections and study of the behaviour of a maximum and minimum frequency relay, verifi cation of its operation at maximum and minimum voltage.
• Connections and study of the behaviour of a phase sequence and voltage asymmetry relay in a three-phase network, verifi cation of its operation with wrong sequence and in non-asymmetric conditions or missing phase.
• Connections and study of the behaviour of a maximum current directional relay in a three-phase network, verifi cation of its operation with reverse current fl ow and as directional of maximum earth current (suitable for lines and generators).
• Use of auxiliary relays as interface of protection relays for controlling high power flows
• Use of auxiliary relays as interface for remote, optical/ acoustic signalling of intervention of protection relays.
• Use of timers with various time functions to increase the functionality of protection relays
• Determination of the transformation ratio of a TA with various primary currents and infl uence of load on the secondary winding, performance tests.
• Connection of current transformers in three-phase networks.
• Measurement of zero sequence current in a three-phase system.
• Tests on a current step-up transformer.
• Demonstration of the differential protection principle.
• Determination of the transformation ratio of a TV with various primary voltages and infl uence of load on the secondary winding, performance tests.
• Connections of voltage transformers in three-phase networks.
• Connections of open-delta voltage transformers in threephase networks.
Supply with 
THEORETICAL – EXPERIMENTAL HANDBOOK